FILE NAME:			CP017706.scexe

TITLE:				HP Mellanox Online Firmware Upgrade Utility for 644160-B21 and 644161-B21 (Linux x86_64) 

VERSION:			1.0.6

REVISION:			1

LANGUAGE:			English

CATEGORY:			Software Solutions

DIVISIONS:			Enterprise and Mainstream Servers

PRODUCTS AFFECTED:
				HP InfiniBand QDR/EN 10Gb Dual Port 544M Adapter    
 				HP InfiniBand FDR/EN 10/40Gb Dual Port 544M Adapter    


OPERATING SYSTEMS:
				Red Hat Enterprise Linux 6 AS/ES for x86_64
				Red Hat Enterprise Linux 5 AS/ES for x86_64
				SUSE LINUX Enterprise Server 11 for x86_64
				SUSE LINUX Enterprise Server 10 for x86_64

PREREQUISITES:  
				None

EFFECTIVE DATE: 		05/24/2011

SUPERSEDES:			CP017330.scexe

DESCRIPTION:			This scexe contains the utilities and firmware binaries 
				for the below adapters used in HP blade servers:
					HP InfiniBand QDR/EN 10Gb Dual Port 544M Adapter: HP Part #644160-B21
					HP InfiniBand FDR/EN 10/40Gb Dual Port 544M Adapter: HP Part #644161-B21


ENHANCEMENTS/FIXES:
				Flashes firmware version 2.10.2280 on the below cards:
					HP InfiniBand QDR/EN 10Gb Dual Port 544M Adapter (Rev B3 with PSID HP_0250230018)
					HP InfiniBand FDR/EN 10/40Gb Dual Port 544M Adapter (Rev B3 with PSID HP_0240230019)
 
Table of Contents
=================
Introduction
Packaging
Performing the Firmware Upgrade
Firmware Upgrade Log
  
			       
Introduction
============
This file describes the firmware upgrade of the HP Mellanox ConnectX3 
InfiniBand adapters mentioned in the PRODUCTS AFFECTED section of this
document.   


Packaging
=========
The firmware upgrade utility is released in scexe format.  The file is a single
self-extracting executable that unpacks the component, runs it, and cleans
up the component. This process replaces the manual process of downloading the firmware
binary to the server, manually flashing the firmware using mstflint and verifying
the firmware version is uptodate. mstflint version 2.7.1-7 is packaged with the 
component to flash the appropriate firmware.


Performing the Firmware Upgrade
===============================

1. The firmware can be upgraded interactively using the following command:

	#./CP00xxxx.scexe 
	
2. Check the help menu for more information regarding command line options.

	#./CP00xxxx.scexe -h


Firmware Upgrade Log
====================

The results to the firmware upgrade are in the mstflint.log  which 
will be written to the current working directory.  
	
Copyright 2011 Hewlett-Packard Development Company, L.P.  Product names 
mentioned herein may be trademarks and/or registered trademarks of their 
respective companies