SUM stops responding
-
SUM takes more time to deploy updates than expected.
-
SUM stops responding when performing inventory on a baseline.
-
SUM shuts down unexpectedly.
-
SUM does not generate any dependency and fails to install when downgrading from iLO 5 1.15 to iLO 5 1.10.
Solution 1Action
Try the following actions.
-
Launch SUM.
-
Run
clean-cache
, and then launch SUM. -
Shut down the SUM engine. Use the command
smartupdate shutdownengine
from the SUM directory. -
Restart the computer and run SUM again.
Solution 2Cause
Action
SUM might not have system or network resources.
Do not deploy more than the 50 nodes at a time, or 10 VMware nodes at a time.
Solution 3Cause
Action
Performing inventory on more than one baseline might use too many system resources.
Perform inventory on one SPP baseline at a time.
Solution 4Cause
Action
SUM does not show any dependency and fails to install because SUM 8.1 does not support iLO downgrade.
Perform the downgrade outside of SUM. Extract iLO 5 Smart Component to a directory and then upload the firmware binary file directly using the iLO 5 interface.