Associated nodes deployment behavior
The following describes which nodes SUM can automatically add and the order in which SUM deploys the nodes:
- Onboard Administrator
-
Types of associated nodes:
-
iLO
-
Virtual Connect
-
SAS Switches
Deployment behavior:
-
Deploys the OA first and then other nodes.
-
- Virtual Connect
-
Types of associated nodes:
-
Onboard Administrator
Deployment behavior:
-
Deploys the VC first and then the OA.
-
- FC Switch
-
Types of associated nodes:
-
Partner FC Switches
Deployment behavior:
-
Deploys to the selected switch first and then to associated switches.
-
- 6 Gb SAS BL Switches
-
Types of associated nodes:
-
Onboard Administrator
Deployment behavior:
-
Deploys to the selected switch first and then to the OA.
-
- iLO
-
Types of associated nodes:
-
Onboard Administrator
-
Server
Deployment behavior:
-
Deploys to the iLO first and then the OA and servers.
-
- Server
-
Types of associated nodes:
-
None
-
- Moonshot
-
Types of associated nodes:
-
None
-
- Superdome X
-
Types of associated nodes:
-
None
-
If you are running a mixed IPv4 and IPv6 environment, SUM might display the following issues:
-
If you add an IPv6 iLO with associated nodes and the associated nodes are only configured with IPv4, SUM displays IPv6 nodes.
-
SUM does not support IPv6 for SAS and FC switches.